Why is my solar plant producing less than its design?
The short answer. A plant falls short of its design because it is losing energy, or because its record is wrong. Both are found by reading generation against the P90 expected yield and the billing meter, not against SCADA alone.
When the record is wrong
- SCADA reads 0.0 in daylight.
- Inverters are left out of the monitoring record. In a survey of three plants, three of seven inverters were not counted.
- Missing data is counted as zero generation. It should be flagged for checking instead.
When the plant is losing energy
- The string voltage falls below the inverter's MPPT voltage range, so power is lost every day. This appears in the weaker designs we have reviewed, and the designers' own energy models carry the loss.
- Rows shade each other on winter afternoons.
- Some cable runs are sized with losses over 2%.
- A fault is marked closed before the billing meter shows the recovery.
How to check
Read each month's generation against the plant's P90 expected yield, adjusted for grid unavailability and weather. Reconcile SCADA data, daily generation reports and billing-meter readings. Where the gap stays, an inspection and testing programme puts each loss in MWh and sets out what fixes it, with its cost and payback.